|
GFTR2 |
210.11(C)(4) |
Garage Branch Circuits |
|
AFTR1 |
210.12(C) and 210.12(D) |
Arc-Fault Circuit-Interrupter Protection |
|
AFTR2 |
210.12(C) and 210.12(D) |
Arc-Fault Circuit-Interrupter Protection |
|
AGTR1 |
210.12(C) and 210.12(D) |
Arc-Fault Circuit-Interrupter Protection |
|
AGTR2 |
210.12(C) and 210.12(D) |
Arc-Fault Circuit-Interrupter Protection |
|
T5320 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
TBR15 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
TCR20 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
T5325 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
TDR15 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
T5820 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
TBR20 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
T5825 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
TDR20 |
210.52(A)(2)(1) |
Dwelling Unit Receptacle Outlets |
|
GFTR2 |
210.52(G) and 210.52(G)(1) |
Dwelling Unit Receptacle Outlets |
|
5280 |
210.64 |
Electrical Service Areas |
|
5380 |
210.64 |
Electrical Service Areas |
|
DDL06-1LZ |
210.70(A)(2)(4) and 210.70(C) |
Lighting Outlets Required |
|
DDL00R-DLZ |
210.70(A)(2)(4) and 210.70(C) |
Lighting Outlets Required |
|
5249-CAP |
210.71 |
Meeting Rooms |
|
5250 |
210.71 |
Meeting Rooms |
|
GFTR1 |
210.8(A)(7) |
Ground-Fault Circuit- Interrupter Protection for Personnel |
|
GFTR2 |
210.8(A)(7) |
Ground-Fault Circuit- Interrupter Protection for Personnel |
|
GFNT1 |
210.8(B)(9), 210.8(B)(10) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
GFNT2 |
210.8(B)(9), 210.8(B)(10) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
GFTA1 |
210.8(B)(9), 210.8(B)(10) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
GFTA2 |
210.8(B)(9), 210.8(B)(10) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
GFRBF |
210.8(E) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
GFTR1 |
210.8(E) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
GFTR2 |
210.8(E) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
GFNT1 |
210.8(E) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
GFNT2 |
210.8(E) |
Ground-Fault Circuit-Interrupter Protection for Personnel |
|
OSSMT-MD |
404.2(C) |
Switch Connections |
|
OSD10-IO |
404.22 |
Electronic Lighting Control Switches |
|
T5320 |
406.12 |
Tamper-Resistant Receptacles |
|
T5820 |
406.12 |
Tamper-Resistant Receptacles |
|
5262-S1 |
406.3(E) |
Receptacle Rating and Type |
|
5362-S1 |
406.3(E) |
Receptacle Rating and Type |
|
T5632 |
406.3(F) |
Receptacle Rating and Type |
|
T5832 |
406.3(F) |
Receptacle Rating and Type |
|
USB4P |
406.3(F) |
Receptacle Rating and Type |
|
AFTR1 |
406.4(D)(4), Ex. No. 1 and Ex. No. 2 |
General Installation |
|
AFTR2 |
406.4(D)(4), Ex. No. 1 and Ex. No. 2 |
General Installation |
|
AGTR1 |
406.4(D)(4), Ex. No. 1 and Ex. No. 2 |
General Installation |
|
AGTR2 |
406.4(D)(4), Ex. No. 1 and Ex. No. 2 |
General Installation |
|
IUM1V |
406.9(B)(1) |
Receptacles in Damp or Wet Locations |
|
IUM1H |
406.9(B)(1) |
Receptacles in Damp or Wet Locations |
|
GFNT1 |
422.5 |
Ground-Fault Circuit-Interrupter (GFCI) Protection for Personnel |
|
GFNT2 |
422.5 |
Ground-Fault Circuit-Interrupter (GFCI) Protection for Personnel |
|
GFRBF |
424.45 |
Installation of Cables Under Floor Coverings |
|
GFTR1 |
424.45 |
Installation of Cables Under Floor Coverings |
|
GFTR2 |
424.45 |
Installation of Cables Under Floor Coverings |
|
GFNT1 |
424.45 |
Installation of Cables Under Floor Coverings |
|
GFNT2 |
424.45 |
Installation of Cables Under Floor Coverings |
|
MDS30-AX |
445.18 |
Disconnecting Means and Shutdown of Prime Mover |
|
DS30-AX |
445.18 |
Disconnecting Means and Shutdown of Prime Mover |
|
16693 |
445.20 |
Ground-Fault Circuit-Interrupter Protection for Receptacles on 15-kW or Smaller Portable Generators |
|
16694 |
445.20 |
Ground-Fault Circuit-Interrupter Protection for Receptacles on 15-kW or Smaller Portable Generators |
|
5262-IG |
517.16 |
Use of Isolated Ground Receptacles. (Health Care Facilities) |
|
5262-SI |
517.16 |
Use of Isolated Ground Receptacles. (Health Care Facilities) |
|
GFA15-3TC |
525.23(D) |
Ground-Fault Circuit-Interrupter (GFCI) Protection. (Carnivals, Circuses, Fairs, and Similar Events) |
|
GFA20-3C |
525.23(D) |
Ground-Fault Circuit-Interrupter (GFCI) Protection. (Carnivals, Circuses, Fairs, and Similar Events) |
|
GFTR1 |
550.13(B) |
Receptacle Outlets. (Mobile Homes, Manufactured Homes, and Mobile Home Parks) |
|
AFTR1 |
550.25(B) |
Arc-Fault Circuit-Interrupter Protection. (Mobile Homes, Manufactured Homes, and Mobile Home Parks) |
|
AFTR2 |
550.25(B) |
Arc-Fault Circuit-Interrupter Protection. (Mobile Homes, Manufactured Homes, and Mobile Home Parks) |
|
AGTR1 |
550.25(B) |
Arc-Fault Circuit-Interrupter Protection. (Mobile Homes, Manufactured Homes, and Mobile Home Parks) |
|
AGTR2 |
550.25(B) |
Arc-Fault Circuit-Interrupter Protection. (Mobile Homes, Manufactured Homes, and Mobile Home Parks) |
|
GFNT2 |
551.71 |
Type Receptacles Provided. (Recreational Vehicle Parks) |
|
G5262-WTI |
555.19(B)(1) |
Receptacles. (Marinas, Boatyards, and Commercial and Noncommercial Docking Facilities) |
|
G5362-WTI |
555.19(B)(1) |
Receptacles. (Marinas, Boatyards, and Commercial and Noncommercial Docking Facilities) |
|
FDBX1 |
600.34, 600.2 |
Photovoltaic (PV) Powered Sign |
|
FDBX2 |
600.34, 600.2 |
Photovoltaic (PV) Powered Sign |
|
FDBX3 |
600.34, 600.2 |
Photovoltaic (PV) Powered Sign |
|
COVER-S |
600.34, 600.2 |
Photovoltaic (PV) Powered Sign |
|
COVER-GS |
600.34, 600.2 |
Photovoltaic (PV) Powered Sign |
|
FDBX1 |
600.6(A)(1), Ex. No. 2 |
Disconnects. (Electric Signs and Outline Lighting) |
|
FDBX2 |
600.6(A)(1), Ex. No. 2 |
Disconnects. (Electric Signs and Outline Lighting) |
|
FDBX3 |
600.6(A)(1), Ex. No. 2 |
Disconnects. (Electric Signs and Outline Lighting) |
|
COVER-GS |
600.6(A)(1), Ex. No. 2 |
Disconnects. (Electric Signs and Outline Lighting) |
|
COVER-S |
600.6(A)(1), Ex. No. 2 |
Disconnects. (Electric Signs and Outline Lighting) |
|
32120-1 |
620.51(E) |
Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts |
|
32277-DY3 |
620.51(E) |
Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts |
|
P1070-10S |
645.18 |
Surge Protection for Critical Operations Data Systems. (Information Technology Equipment) |
|
P1071-10S |
645.18 |
Surge Protection for Critical Operations Data Systems. (Information Technology Equipment) |
|
32120-1 |
670.6 |
Surge Protection. (Industrial Machinery) |
|
32277-DY3 |
670.6 |
Surge Protection. (Industrial Machinery) |
|
FDBX3 |
680.12 and 680.14 |
Equipment Rooms and Pits. (Swimming Pools, Fountains, and Similar Installations) and 680.14 Corrosive Environment |
|
COVER-S |
680.12 and 680.14 |
Equipment Rooms and Pits. (Swimming Pools, Fountains, and Similar Installations) and 680.14 Corrosive Environment |
|
COVER-GS |
680.12 and 680.14 |
Equipment Rooms and Pits. (Swimming Pools, Fountains, and Similar Installations) and 680.14 Corrosive Environment |
|
FDBX1 |
680.12 and 680.14 |
Equipment Rooms and Pits. (Swimming Pools, Fountains, and Similar Installations) and 680.14 Corrosive Environment |
|
FDBX2 |
680.12 and 680.14 |
Equipment Rooms and Pits. (Swimming Pools, Fountains, and Similar Installations) and 680.14 Corrosive Environment |
|
G5262-WTI |
680.2 and Part VIII of Article 680 |
Definitions, Swimming Pools, Fountains, and Similar Installations |
|
G5362-WTI |
680.2 and Part VIII of Article 680 |
Definitions, Swimming Pools, Fountains, and Similar Installations |
|
G5262-WTI |
680.22(A)(2) |
Lighting, Receptacles, and Equipment. (Swimming Pools, Fountains, and Similar Installations) |
|
G5362-WTI |
680.22(A)(2) |
Lighting, Receptacles, and Equipment. (Swimming Pools, Fountains, and Similar Installations) |
|
G5262-WTI |
680.28 |
Gas-Fired Water Heater. (Swimming Pools, Fountains, and Similar Installations) |
|
G5362-WTI |
680.28 |
Gas-Fired Water Heater. (Swimming Pools, Fountains, and Similar Installations) |
|
G5262-WTI |
682.15 |
Ground-Fault Circuit-Interrupter (GFCI) Protection. (Natural and Artificially Made Bodies of Water) |
|
G5362-WTI |
682.15 |
Ground-Fault Circuit-Interrupter (GFCI) Protection. (Natural and Artificially Made Bodies of Water) |
|
32120-1 |
695.15 |
Surge Protection. (Fire Pumps) |
|
32277-DY3 |
695.15 |
Surge Protection. (Fire Pumps) |
|
6210G-3W |
725.144, Table 725.144 |
Transmission of Power and Data. (Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits) |
|
6AS10-3W |
725.144, Table 725.144 |
Transmission of Power and Data. (Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits) |
|
6210G-3W |
840.160 |
Powering Circuits |
|
6AS10-3W |
840.160 |
Powering Circuits |