| Article | Description | Related Leviton Video Resource | 
| 100 | Definition of Readily Accessible | NA | 
| 110.14(D) | Torque Tool Requirements on Installations | NA | 
| 210.8(A)(7) | Measurement for GFCI's Around Sinks | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 210.8(B) | Three-Phase GFCI Protection | NA | 
| 210.8(B)(9) & 
 210.8(B)(10)
 | GFCI Protection in Non-Dwelling Crawl Spaces & Unfinished Basements | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 210.8(E) | GFCI Protection for Lighting in Crawl Spaces | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 210.11(C)(4) | Garage Branch Circuit(s) | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 210.12(C) & 
 210.12(D)
 | AFCI Protection in Guest Rooms, Guest Suites and Dormitories | Introducing the new SmartlockPro® AFCI Receptacle from Leviton 
 Leviton Presents: How to Install an AFCI Outlet
 
 Leviton Presents: Modifications/Extensions to Existing Branch Circuits for 2014 NEC 210.12(B) Code
 
 Leviton Presents: Replacing a Receptacle on an Existing Branch Circuit for 2014 NEC 406.4 (D) Code
 | 
| 210.52(A)(2)(1) | Receptacle Wall Space Requirements - Fixed Cabinets w/o Countertop | Introducing the new SmartlockPro® AFCI Receptacle from Leviton 
 Leviton Presents: How to Install an AFCI Outlet
 
 Leviton Presents: Modifications/Extensions to Existing Branch Circuits for 2014 NEC 210.12(B) Code
 
 Leviton Presents: Replacing a Receptacle on an Existing Branch Circuit for 2014 NEC 406.4 (D) Code
 | 
| 210.52(G) & 
 210.52(G)(1)
 | Receptacles for Basements, Garages and Accessory Buildings | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 210.64 | Receptacle at Electric Service Areas | Whole House Surge Protection How to Install a Leviton Commercial Surge Receptacle
 | 
| 210.70(A)(2)(4) & 
 210.70(C)
 | Lighting Outlet(s) Required | Decora Digital Controls with Bluetooth Technology makes Lighting Control Easy Introducing the Decora® Z-Wave Line of Products from Leviton
 Introducing the CFL Lampholder Line of Products from Leviton | 
| 210.71 | Receptacles in Meeting Rooms | Tamper Resistant Floor Box Assemblies | 
| 250.52(B)(3) | Pool Structures Not Permitted for Grounding Electrodes | NA | 
| 250.94(A) and (B) | Bonding of Communication Systems | Leviton Network Solutions - The Smart Choice for a Better Network | 
| 250.148 | Continuity and Attachment of EGC to Boxes | NA | 
| 312.8(B) | Switch and Overcurrent Device Enclosures - Allowance for Power Monitoring Equipment | Leviton Building Manager Online (BMO) 2.0 VerifEye™ Submetering Solutions
 Energy Monitoring Hub - Installation & Commission
 Leviton EMH+ Submetering Hub
 | 
| 404.2(C) | Switch Connections - Neutrals at Switch Locations | Introducing the Univeral Occupancy and Vacancy Sensor Line from LevitonOccupancy Sensor Installation - ODS10
 | 
| 404.22 | Construction Specifications of Electronic Lighting Controls | Introducing the Univeral Occupancy and Vacancy Sensor Line from LevitonOccupancy Sensor Installation - ODS10
 | 
| 406.3(E) | Controlled Receptacle Marking | NA | 
| 406.3(F) | Receptacle Rating and Type - USB Charger Receptacle | Introducing the USB Charger / Tamper Resistant Outlet from Leviton Introducing USB Charger Devices from Leviton
 Introducing the 4-Port USB Charger Outlet from Leviton
 | 
| 406.4(D)(4) 
 EX 1 & 2
 | AFCI Replacement Receptacles | Introducing the new SmartlockPro® AFCI Receptacle from Leviton 
 Leviton Presents: How to Install an AFCI Outlet
 Leviton Presents: Modifications/Extensions to Existing Branch Circuits for 2014 NEC 210.12(B) Code
 Leviton Presents: Replacing a Receptacle on an Existing Branch Circuit for 2014 NEC 406.4 (D) Code
 | 
| 406.9(B)(1) | Extra Duty Outlet Box Hoods | How to Install a Leviton Weatherproof Extra-Duty Outlet Box Hood (While-In-Use Cover) While In Use Covers
 | 
| 406.12 | Tamper-Resistant Receptacles - Additional Required Locations | Leviton Presents: How to Install a Tamper Resistant Receptacle | 
| 406.15 | Article Deletion - Dimmer Controlled Receptacles | NA | 
| 422.5 | GFCI Protection for Appliances | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 422.16(B)(2) | Built-In Dishwashers - Cords and Receptacle Requirements | Leviton Receptacles Leviton Presents: How to Install an Electrical Wall Outlet
 | 
| 424.45 | Heating Cables Under Floor Coverings | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 445.18 | Disconnecting Means & Shutdown of Prime Mover - Generator | NA | 
| 445.20 | GFCI Protection for Receptacles on 15-KW or Smaller Generators | Leviton Portable GFCI | 
| 517.16 | Use of Isolated Ground Receptacles | Isolated Ground GFCI Receptacles | 
| 517.30 | Sources of Power - Health Care Facilities | NA | 
| 525.23(D) | GFCI Protection at Carnivals, Circuses, Fairs, and Similar Events | Leviton Portable GFCI | 
| 550.13(B) | GFCI Protection Required for Mobile and Manufactured Homes | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 550.25(B) | AFCI Protection at Mobile and Manufactured Homes | Introducing the new SmartlockPro® AFCI Receptacle from Leviton 
 Leviton Presents: How to Install an AFCI Outlet
 Leviton Presents: Modifications/Extensions to Existing Branch Circuits for 2014 NEC 210.12(B) Code
 Leviton Presents: Replacing a Receptacle on an Existing Branch Circuit for 2014 NEC 406.4 (D) Code
 | 
| 551.71 | Receptacles at RV Parks | Leviton Presents: How to Install an Electrical Wall Outlet | 
| 555.3 | GFCI Protection for Docking Facilities | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 555.19(B)(1) | GFCI Protection for Personnel in Boatyards | Smartlock Pro Self Test GFCI from Leviton UL943 Self-Test GFCI End of Life
 | 
| 555.24 | Signage At Marinas, Boatyards, etc. | NA | 
| 600.4(B) | Signs with a Retrofit Illumination System | NA | 
| 600.6(A)(1) 
 Ex #2
 | Disconnects - Electric Signs and Outline Lighting | NA | 
| 600.34, 600.2 | Photovoltaic (PV) Powered Signs | NA | 
| 620.51 (E) | Surge Protection - Emergency System Elevators, Escalators, etc. | Whole House Surge Protection How to Install a Leviton Commercial Surge Receptacle
 | 
| 645.18 | Surge Protection for Critical Operations Data Systems | Whole House Surge Protection How to Install a Leviton Commercial Surge Receptacle
 | 
| 670.6 | Surge Protection for Industrial Machinery | Whole House Surge Protection How to Install a Leviton Commercial Surge Receptacle
 | 
| 680.2 & Part VIII of 680 (680.80, 680.81, 680.82, 680.83, 680.84, 680.85)
 | Swimming Pool Lifts | Smartlock Pro Self Test GFCI from Leviton UL943 Self-Test GFCI End of Life
 | 
| 680.12 and 680.14 | Protection Against Corrosive Environments in Wet Locations | Rhino-Hide® LZ Series Multi-Pin Connectors Rhino-Hide® NEMA Wiring Devices
 Leviton Wetguard® Watertight Wiring Devices
 How to Install Leviton Wetguard Watertight Plugs and Connectors
 Leviton Introduces Wetguard Stainless Steel FD Boxes
 | 
| 680.22(A)(2) | Pool Pump Motor Receptacles | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 680.28 | Swimming Pools Gas-Fired Water Heater | 			Smartlock Pro Self Test GFCI from Leviton
 UL943 Self-Test GFCI End of Life
 | 
| 682.15 | GFCI Protection in Bodies of Water | 			Smartlock Pro Self Test GFCI from LevitonUL943 Self-Test GFCI End of Life
 | 
| 695.15 | Surge Protection - Fire Pumps | Whole House Surge Protection How to Install a Leviton Commercial Surge Receptacle
 | 
| 700.2 and 700.25 | Branch Circuit Emergency Lighting Transfer Switch | NA | 
| 700.10(A) | Marking of Boxes, Enclosures, Receptacles For Emergency Circuits or Systems | NA | 
| 702.12(C) | Power Inlets Used with Optional Standby Generators | NA | 
| 705 Part IV | Microgrid Systems | NA | 
| 706 | Energy Storage Systems | NA | 
| 708.10(A)(2) | Illuminated Faces or Indicator Lights on COPS Receptacles | NA | 
| 710 | Stand Alone Systems | NA | 
| 712 | Direct Current Microgrids | NA | 
| 725.144 | Transmission of Power & Data Over Data Cables | Leviton Network Solutions Cat 6A UTP System | 
| 840.160 | Powering Circuits | NA |